Modifier QE
Oxygen Flow Below 1 LPM
Modifier QE identifies stationary oxygen equipment prescribed at a flow rate of less than one liter per minute (LPM). Medicare uses this modifier to determine the applicable payment adjustment for qualifying oxygen equipment claims.
On This Page
Related Modifiers
Low Oxygen Day/Night Average
High-Flow Stationary Oxygen
Rental Equipment
What Is Modifier QE?
Modifier QE is a HCPCS Level II modifier used in Medicare billing to identify stationary oxygen equipment furnished to beneficiaries whose prescribed oxygen flow requirement is less than 1 liter per minute (LPM) at rest.
Medicare uses this modifier to distinguish low-flow oxygen requirements from standard and high-flow oxygen prescriptions. Because lower oxygen flow rates generally require less oxygen delivery capacity, Medicare applies a specific payment adjustment to qualifying stationary oxygen equipment.
When Modifier QE applies, Medicare reduces the applicable stationary oxygen equipment payment amount by 50%. This adjustment affects reimbursement for eligible equipment and does not automatically apply to every oxygen-related service or supply.
Modifier QE is commonly associated with stationary oxygen equipment, including oxygen concentrators, when the beneficiary's documented flow requirement meets Medicare's low-flow criteria. Suppliers must verify the prescribed flow rate, qualifying test information, and applicable billing requirements before submitting the claim.
Important: Modifier QE identifies a qualifying low-flow oxygen requirement for payment purposes. It does not independently establish medical necessity, determine coverage eligibility, or replace Medicare's oxygen equipment documentation requirements.
Quick Reference
Modifier: QE
Meaning: Oxygen Below 1 LPM
Category: DMEPOS
Type: HCPCS Level II
Equipment: Stationary Oxygen
Payment: 50% Reduction
When to Use Modifier QE
Oxygen Flow Below 1 LPM
Report QE when the beneficiary's qualifying oxygen flow requirement at rest is less than 1 LPM.
Stationary Oxygen Equipment
Use QE with eligible stationary oxygen equipment when Medicare's low-flow payment adjustment applies.
Medicare DMEPOS Claims
Append QE when required to identify the qualifying oxygen flow rate on applicable Medicare claims.
Documented Oxygen Prescription
The treating practitioner's order and supporting medical records must establish the prescribed oxygen flow requirement.
Important: A flow rate of exactly 1 LPM does not qualify for Modifier QE.
When NOT to Use Modifier QE
Oxygen Flow of 1 LPM or Higher
Do not report QE when the qualifying at-rest oxygen flow requirement is 1 LPM or greater.
High-Flow Oxygen
Do not use QE when the qualifying oxygen flow requirement exceeds 4 LPM. Modifier QG may apply.
Different Daytime and Nighttime Flows
When daytime and nighttime prescriptions differ, Modifier QA may apply if the qualifying average is below 1 LPM.
Portable Oxygen Equipment
Do not use QE solely to identify portable oxygen equipment. The modifier applies to the qualifying stationary oxygen payment adjustment.
Exercise-Only Oxygen Flow
Do not select QE solely from an exercise flow rate when Medicare requires the qualifying at-rest oxygen flow rate.
Modifier QE vs. QA and QG
These modifiers identify different oxygen flow requirements and should not be used interchangeably.
Modifier QE – Low-Flow Oxygen
Purpose: Identifies stationary oxygen flow below 1 LPM.
When Used: Qualifying at-rest oxygen requirement is less than 1 LPM.
Payment Impact: 50% stationary oxygen payment reduction.
Modifier QA – Day/Night Oxygen Flow
Purpose: Identifies low average oxygen flow when daytime and nighttime requirements differ.
When Used: The qualifying average flow is below 1 LPM.
Payment Impact: Applicable low-flow payment adjustment.
Modifier QG – High-Flow Oxygen
Purpose: Identifies stationary oxygen flow exceeding 4 LPM.
When Used: Qualifying at-rest oxygen requirement exceeds 4 LPM.
Payment Impact: Applicable high-flow payment adjustment.
Key Difference: QE identifies low-flow oxygen at rest, QA addresses different daytime and nighttime flow rates with a qualifying low average, and QG identifies high-flow oxygen requirements.
Billing Example
A Medicare beneficiary qualifies for home oxygen therapy and receives a stationary oxygen concentrator.
The documented oxygen flow requirement at rest is 0.5 LPM.
Example – Low-Flow Stationary Oxygen
Equipment: Stationary Oxygen Concentrator
Prescribed Flow: 0.5 LPM
Modifier: QE
Example Claim: E1390-RR-QE
Modifier RR identifies rental equipment, while Modifier QE identifies the qualifying low-flow oxygen requirement.
The eligible stationary oxygen equipment payment is subject to Medicare's 50% low-flow reduction.
Important: This example assumes Medicare coverage criteria are met. Additional required modifiers and documentation rules may apply.
Documentation Requirements
Documentation must support the beneficiary's oxygen requirements and the equipment furnished.
Standard Written Order
Maintain a valid order containing the information required under Medicare DMEPOS documentation rules.
Qualifying Oxygen Test
Retain qualifying oxygen test results and supporting clinical records establishing coverage eligibility.
Prescribed Flow Rate
Document the oxygen flow requirement in liters per minute, including the applicable at-rest flow rate.
Equipment Identification
Record the stationary oxygen equipment supplied and its corresponding HCPCS code.
Medical Necessity
Maintain clinical documentation supporting the beneficiary's need for home oxygen therapy.
Documentation Checklist
Valid oxygen equipment order
Qualifying oxygen test documented
At-rest flow requirement verified
Prescribed flow below 1 LPM
Stationary equipment code confirmed
Medicare coverage requirements reviewed
Medicare Oxygen Billing Rules
Medicare adjusts payments for qualifying stationary oxygen equipment according to the applicable prescribed oxygen flow requirement.
Low-Flow Payment Reduction
When Modifier QE applies, Medicare reduces the qualifying stationary oxygen equipment payment amount by 50%.
Stationary Equipment
The reduction applies to eligible stationary oxygen equipment and does not automatically reduce every oxygen-related claim line.
Different Daytime and Nighttime Flows
When prescribed daytime and nighttime flow rates differ, Medicare uses the applicable averaging rules to determine whether Modifier QA is appropriate.
Oxygen Equipment Rental
Stationary oxygen equipment is subject to Medicare's oxygen equipment rental and payment policies. Modifier RR may also apply when reporting rental equipment.
Coverage Requirements
Modifier QE does not replace Medicare's qualifying oxygen testing, medical necessity, order, or other claim documentation requirements.
Important: Suppliers should report the appropriate modifiers and allow Medicare to calculate the payment adjustment rather than manually reducing submitted charges.
Common Billing Errors & Denials
Reporting QE for Exactly 1 LPM
Modifier QE requires a qualifying oxygen flow rate below 1 LPM. A documented requirement of exactly 1 LPM does not meet this threshold.
Using an Exercise-Only Flow Rate
Selecting QE based on an exercise oxygen requirement instead of the applicable at-rest flow rate can result in incorrect billing.
Confusing QE and QA
When daytime and nighttime oxygen flow requirements differ, the qualifying average may require Modifier QA rather than QE.
Missing Oxygen Flow Documentation
Failing to document the prescribed oxygen flow rate may prevent verification of the correct payment adjustment.
Incorrect Equipment Code
Appending QE to an ineligible oxygen equipment code may result in billing inconsistencies or claim denials.
Missing Required Coverage Modifiers
Reporting QE does not eliminate the need for other applicable Medicare oxygen coverage modifiers.
Understanding Related Claim Denials
CO-4 – Procedure Code and Modifier Inconsistency
May apply when a modifier is incompatible with the reported equipment code or a required modifier is missing.
CO-16 – Missing or Incomplete Information
May apply when required claim information is missing or incomplete.
For additional denial code explanations, visit DenialCodeLookup.com.
Frequently Asked Questions
Can Modifier QE be used when a patient needs a higher oxygen flow rate during exercise?
The applicable Medicare flow-rate determination generally relies on the qualifying at-rest requirement rather than the exercise flow rate. Suppliers must follow Medicare's oxygen policy when evaluating different prescribed flow rates.
Does Modifier QE change the Medicare oxygen equipment rental period?
No. Modifier QE identifies a payment adjustment based on the qualifying oxygen flow requirement. It does not independently change Medicare's oxygen equipment rental period or continued coverage requirements.
ModifierLookup
Your trusted source for CPT and HCPCS modifier explanations, billing guidance, and coding resources
Categories
© 2025. All rights reserved.
Modifiers
Guides
Resources
Trusted Information
Practical Guidance
Accurate, up-to-date, and compliance-focused modifier guidance
Real-world billing examples and coding insights
Built for Professionals
Designed for coders, billers, and healthcare teams
Billing Guidelines
NCCI Edits Guide
Medicare Guidelines
Privacy Policy
Terms & Conditions
Sitemap