Home / All Categories / Radiology Modifiers / Modifier CT
Modifier CT
Noncompliant CT Equipment
Modifier CT identifies computed tomography (CT) services performed using equipment that does not meet NEMA XR-29-2013 standards. Medicare uses this modifier to apply payment reductions to eligible CT imaging services.
On This Page
Related Modifiers
Modifier TC
Technical Component
Modifier 26
Professional Component
Modifier FY
Computed Radiography
What Is Modifier CT?
Modifier CT is a HCPCS Level II modifier used to identify eligible CT imaging services performed using equipment that does not meet the NEMA XR-29-2013 standards.
These standards address important CT equipment capabilities, including radiation dose optimization, dose reporting, and safety-related technology.
Medicare established payment reductions for certain CT services performed using noncompliant equipment to encourage the adoption of technology that supports radiation dose management.
Important: Modifier CT identifies equipment compliance status. It does not indicate that the imaging service was medically unnecessary or that the scan was performed incorrectly.
Quick Reference
Modifier: CT
Type: HCPCS Level II
Category: Radiology Modifiers
Meaning: Noncompliant CT Equipment
Billing: Medicare CT Services
Payment: Technical Component Reduction
When to Use Modifier CT
Noncompliant CT Equipment
Report Modifier CT when an eligible CT examination is performed using equipment that does not meet all NEMA XR-29-2013 requirements.
Eligible Medicare Services
Append CT to applicable procedure codes when Medicare requires identification of noncompliant CT equipment.
Technical Component Billing
Use CT when the eligible service includes the technical imaging component performed using noncompliant equipment.
Hospital Outpatient Services
Report CT for qualifying hospital outpatient CT examinations subject to Medicare's equipment compliance payment rules.
Important: Modifier CT must reflect the actual scanner used for the examination, not the facility's general equipment inventory.
When NOT to Use Modifier CT
Compliant CT Equipment
Do not report CT when the scanner meets all applicable NEMA XR-29-2013 requirements.
Professional Interpretation Only
Do not append CT to a separately billed professional interpretation that does not include the technical imaging component.
Other Imaging Modalities
Do not use CT for MRI, ultrasound, conventional X-ray, or other imaging services outside the applicable CT policy.
Ineligible CT Procedures
Do not report CT when the procedure is excluded from Medicare's noncompliant equipment payment policy.
Unverified Equipment Status
Do not assume a scanner is noncompliant solely because it is older. Verify its technical capabilities before reporting CT.
NEMA XR-29 Equipment Standards
NEMA XR-29-2013 establishes four CT equipment capabilities related to radiation dose management.
DICOM Radiation Dose Structured Reporting
Supports standardized recording and communication of radiation dose information.
Pediatric and Adult Reference Protocols
Provides reference imaging protocols appropriate for different patient populations.
CT Dose Check
Supports notifications and alerts associated with selected radiation dose settings.
Automatic Exposure Control
Adjusts radiation output based on patient characteristics and examination requirements.
Key Point: Equipment must meet all four required capabilities to satisfy the standard. A scanner lacking one or more attributes may be considered noncompliant.
Modifier CT vs 26 and TC
Modifier CT – Noncompliant CT Equipment
Purpose: Identifies noncompliant CT equipment.
When Used: Eligible CT examinations performed using equipment that fails NEMA XR-29 requirements.
Billing Impact: Medicare equipment-related payment reduction.
Modifier 26 – Professional Component
Purpose: Identifies professional interpretation.
When Used: Only the physician's professional component is billed.
Billing Impact: Professional-component reimbursement.
Modifier TC – Technical Component
Purpose: Identifies the technical portion of a diagnostic service.
When Used: Only the technical component is billed.
Billing Impact: Technical-component reimbursement.
Key Difference: Modifier CT identifies equipment compliance, while Modifiers 26 and TC identify which component of the diagnostic service is billed.
Billing Example
A Medicare beneficiary undergoes a CT scan of the abdomen and pelvis with contrast at an outpatient imaging center.
The facility uses a scanner that does not meet NEMA XR-29-2013 standards. The radiologist separately bills the professional interpretation.
Example – CT Abdomen and Pelvis With Contrast
CPT Code: 74177
Service: CT Abdomen and Pelvis With Contrast
Equipment: Noncompliant CT Scanner
Billing: Technical Component
Example Claim: 74177-TC-CT
Explanation: Modifier TC identifies the technical component, while Modifier CT identifies the noncompliant equipment used for the examination.
Important: This example assumes that the service qualifies for Medicare's payment reduction and that the technical component is separately billed.
Documentation Requirements
Documentation must support the CT examination and the compliance status of the equipment used.
Equipment Identification
Maintain records identifying the specific scanner used for the examination.
Compliance Verification
Retain manufacturer specifications, technical assessments, or other reliable documentation establishing the scanner's NEMA XR-29 status.
Procedure Documentation
Document the examination performed, anatomical region, and imaging protocol.
Billing Verification
Confirm that the procedure qualifies for the payment adjustment and that the appropriate billing component is reported.
Documentation Checklist
CT scanner identified
Equipment compliance verified
Imaging procedure documented
Correct CPT code selected
Technical component confirmed
Medicare requirements reviewed
Medicare Payment Rules
Medicare reduces payment for eligible CT services performed using equipment that does not meet NEMA XR-29-2013 standards.
Payment Reduction
2016: 5% reduction.
2017 and Later: 15% reduction.
Technical Component
The reduction applies to the eligible technical portion of the CT service.
Professional Component
A separately billed physician interpretation is not subject to the equipment-related reduction.
Global Billing
When an eligible CT service is globally billed, the reduction applies to the technical portion of the payment.
Hospital Outpatient Billing
The reduction also applies to eligible hospital outpatient services under Medicare's Outpatient Prospective Payment System, according to applicable payment rules.
Important: Medicare applies the payment adjustment through its reimbursement methodology. Providers should not automatically reduce submitted charges by 15%.
Common Billing Errors and Denials
Reporting CT for Compliant Equipment
Appending Modifier CT when the scanner meets NEMA XR-29 standards can result in an unnecessary Medicare payment reduction.
Missing Modifier CT
Failing to report CT for an eligible service performed using noncompliant equipment may result in incorrect reimbursement.
Incorrect Professional Component Billing
Appending CT to a professional-only interpretation when the claim does not include the technical imaging service.
Using CT on Ineligible Procedures
Reporting Modifier CT without verifying that the procedure is subject to Medicare's equipment-related payment policy.
Insufficient Equipment Documentation
Failing to maintain records confirming the scanner's compliance status may create problems during audits or claim reviews.
Confusing Equipment Age With Compliance
Assuming older scanners are automatically noncompliant without verifying their technical capabilities.
Related Payment Adjustments
Medicare may report equipment-related payment reductions using the following remittance codes.
CARC 237 – Legislated/Regulatory Penalty
Identifies a payment adjustment resulting from a statutory or regulatory requirement.
RARC N759 – NEMA XR-29 Adjustment
Indicates that payment was adjusted based on the NEMA XR-29-2013 equipment standard.
For additional claim adjustment and denial code explanations, visit DenialCodeLookup.com.
Frequently Asked Questions
Does Modifier CT apply after a noncompliant scanner has been upgraded?
Not necessarily. If an upgrade brings the scanner into compliance with all applicable NEMA XR-29-2013 requirements, Modifier CT should no longer be reported solely because the equipment was previously noncompliant. Maintain documentation confirming the upgraded equipment's compliance status.
Can Modifier CT and Modifier TC be reported together?
Yes. When separately billing the technical component of an eligible CT examination performed using noncompliant equipment, both modifiers may be appropriate. Modifier TC identifies the technical component, while CT identifies equipment compliance status.
ModifierLookup
Your trusted source for CPT and HCPCS modifier explanations, billing guidance, and coding resources
Categories
© 2025. All rights reserved.
Modifiers
Guides
Resources
Trusted Information
Practical Guidance
Accurate, up-to-date, and compliance-focused modifier guidance
Real-world billing examples and coding insights
Built for Professionals
Designed for coders, billers, and healthcare teams
Billing Guidelines
NCCI Edits Guide
Medicare Guidelines
Privacy Policy
Terms & Conditions
Sitemap